Industrial 4-Ch RS485/RS232 Digital Input/Output Module with Modbus RTU Protocol, Isolation Protection
$30.99
⚠️ Hardware Sub-Model Selection Required
The Analog Input (AI) format is hardware specific and needs to be validated prior to leaving the factory. The output cannot be changed between 4-20mA, 0-5V, or 0-10V by software. Please choose the correct AI sub-model from the drop-down menu before adding to cart.
Product Overview
The Valtoris 4CH-IO-RS232/485 is an industrial Remote I/O Controller for connecting field sensors to legacy RS485 or RS232 networks. It comes with native 4 Digital Inputs, 2 Analog Inputs and 4 Relay Outputs. It is a powerful edge device for SCADA data acquisition and remote control using the standard Modbus RTU protocol.
Quick Specs & Capabilities
- Network Interface: RS485 (default 9600 bps). Supports Modbus RTU.
- Digital I/O: 4x DI (Active/Passive compatible), 4x DO (Relay 5A@250VAC/30VDC).
- Analog Inputs: 2x AI (10-bit accuracy). Configured at factory (4~20mA, 0~5V, 0~10V, Resistance 0-10K).
- Performance: Fast relay response time (<30ms).
- Power & Size: DC 9~24V wide voltage. Ultra-low <1.7W operating consumption. Dimensions: 12.2 cm × 7.2 cm × 3.4 cm.
- Environment: Extreme operating temp (-40°C ~ 85°C). Includes DIN-rail mount.
| Hardware & Interfaces | |
| Serial Port | RS485 interface (1200~115200 bps, default 9600 bps) |
| Power Input | DC 9~24V (Terminal Block) |
| Power Consumption | < 1.7W, < 70mA @ 24V DC |
| I/O Configuration | |
| Digital Inputs (DI) | 4 Channels (Passive Dry Contact or Active Level 9V/24V) |
| Digital Outputs (DO) | 4 Channels (Relay Output: 5A@250VAC / 30VDC) |
| Analog Inputs (AI) | 2 Channels (10-bit accuracy) |
| AI Sub-models | Current (4~20mA, 0~20mA), Voltage (0~5V, 0~10V), or Resistance (0~10K) |
| Software & Performance | |
| Protocols | Modbus RTU |
| Response Time | < 30ms |
| Mechanical & Environment | |
| Dimensions | 12.2 cm × 7.2 cm × 3.4 cm (L x W x H) |
| Operating Temp. | -40°C ~ +85°C |