Industrial LoRa to Ethernet gateway, LoRa to TCP/IP & RS232/485/422 Converter with Modbus Support
$48.99

Our LoRa adapters must be used in pairs:
For RS485/232/422 to LoRa to RS485/232/422, we recommend VT-LR600 +VT-LR600.
For RS485/232/422 to LoRa to Ethernet adapters, we recommend VT-LR600 + VT-LR601.
Please purchase VT-LR600 at same time, purchase link as below:

The Valtoris LORA products can be applied to:
- Power electronics, intelligent instruments;
- Industrial automation system;
- The Internet of things; Climate and geological monitoring
- Building/access/security control system






Outline dimensions

| Appearance | |
| Interface: | 485/422: Terminal; 232: DB9; Ethernet: RJ45 |
| Power Supply: | Inside positive outside negative, standard outlet |
| Size: | L x W x H =9.4cm×6.5cm×2.5cm |
| Specification Parameters | |
| Working Voltage | DC9~24V |
| Working Current | VT-LR600:30mA@12V |
| VT-LR601:160mA@12V | |
| Operating temperature | -40℃~85℃ |
| Humidity | <95%RH |
| Wireless Communication | |
| Transmission Distance | The outdoor area has no shelter of 6km~8km, and the indoor area crosses about 5 floors |
| Frequency Range | 410MHz~525MHz |
| Wireless Channel | 115 |
| Receiving Sensity | -140dbm |
| Transmit Power | 20dbm |
| Modulation System | LoRa™ Patented modulation technology |
| Wireless Connection | External SMA male antenna, suction cup antenna 1 meters; Working frequency: 490MHz |
| Wire Communication | |
| Serial Port Data | Baud Rate:1200~115200bps;Check Bits:None, Even, Odd;Digit 8;Stop bits 1 |
| Ethernet Protocol | (Only VT-LR601 support TCP/IP protocol)ETHERNET、 IP、 TCP、 UDP、 HTTP、 ARP、 ICMP、 DHCP、 DNS |
| Environment | |
| Operating temperature | -40~85℃ |
| Storage temperature | -45~165℃ |
| Humidity range | 5~95% relative humidity |